EVO™ Series Accessories
EVO™ Series Accessories
Interface modules, dispenser interface module cables, and paper supplies.
EVO™ 600 and EVO™ 6000 Interface Modules
The EVO™ 600 and EVO™ 6000 come standard witha Power Supply Module and a Controller Module. Additional interface modules can be installed. Interface modules ordered with an EVO™ will be installed at the factory (FMP-/TS-). If you would like them to not be installed, please order the spare/replacement version of the module (FMSP-/TSSP-).
- EVO™ 600: 6 total modules can be installed with a maximum of 4 intrinsically safe modules.
- EVO™ 6000: 11 total modules can be installed with a maximum of 9 intrinsically safe modules.
The following guidelines must be followed:
- AC Input, 2-Wire Sensor, and 3-Wire Sensor Modules
- No limits - Relay ++ 10A Relay ++ Input Output Modules
- Must be < 4 - UDP 24V
- Must be < 4 - 4-20 mA ++ RS-485
- Depends on how many UDP 24V modules are being used.
| Total UDP 24V Modules | Allowable 4-20 mA + RS-485 Modules |
| 0 or 1 | 4 |
| 2 | 3 |
| 3 | 1 |
| 4 | 0 |
NOTE: If your application requires exceeding the module guidelines, please contact your sales representative.
Pre-Installed Intrinsically Safe Modules
| Model Number | Description |
|---|---|
| TS-2WSNS | Pre-Installed 2-Wire Sensor Module | 12 inputs | Compatible with FMP-HFS2, FMP-UHS, FMP-ULS, TSP-HLS-XX, and TSP-HLS-XX/SS sensors |
| TS-3WSNS | Pre-Installed 3-Wire Sensor Module | 8 inputs | Compatible with FMP-DDS*, FMP-DIS*, FMP-DTS*, FMP-EIS*, FMP-HIS*, FMP-HIS-XL*, FMP-UHS*, FMP-ULS*, TSP-DVS, TSP-HLS-XX, and TSP-HLS-XX/SS sensors |
| TS-PRB | Pre-Installed Probe Module | 12 inputs | Compatible with TSP-LL2-XXX, TSP-LL2-XXX-I, FMP-LL3-XXX, and FMP-LL3-XXX-I probes; TSP-DMS-XX and FMP-XXX-U sensors; and VFM vapor flow meters |
| TS-420IB | Pre-Installed 4-20 mA Module | 8 inputs | Intrinsically Safe | Compatible with TS-LSU500/X transducers and FMP-TEM, TS-VPS, and TS-SCCM sensors |
- -U sensors are not supported on the 2-wire or 3-wire sensor module.
Pre-Installed Non-Intrinsically Safe Modules
| Model Number | Description |
|---|---|
| TS-10ARLY | Pre-Installed 10 Amp Relay Module | 6 outputs | 10 Amp | Compatible with high power dispenser shutdown control functions |
| TS-420EXP | Pre-Installed 4-20 mA Module | 8 inputs | Explosion-Proof | Compatible with TS-LSU500/X transducers and FMP-TEM, TS-VPS, and TS-SCCM sensors |
| TS-ACI | Pre-Installed AC Input Module | 12 inputs | Compatible with dispenser hook signal monitoring functions |
| TS-IO | Pre-Installed Input Output Module | 4 4-20 mA outputs | 8 3-240 VAC/DC inputs | Compatible with remote monitoring control and building monitoring system interfacing functions |
| TS-RLY | Pre-Installed Relay Module | 8 outputs | 2 Amp | Compatible with TS-LSU500/X transducers, TPI, and TS-SCCM control functions |
- TS-RLY Module is not required for STP control when utilizing turbine pump interface (TPI) communications. The TS-420EXP module requires Controller Module software version 9.5 or greater Do not include Power Supply and Controller Module when calculating total modules allowed.
Dispenser Interface Module Cables
| Model Number | Description |
|---|---|
| TSP-BDCBL | Bennett® 515 only cable |
| TSP-GDCBL | Gilbarco™ cable |
| TSP-GSDCBL | Gilbarco™ G-Site™ cable |
| TSP-WDCBL | Wayne™ cable |
Printer Paper Supplies
| Model Number | Description |
|---|---|
| TS-TP2 | One box of 5 rolls of thermal printer paper for fuel management system and Tank Sentinel® consoles |
| TS-TP2C | One case of 20 boxes of 5 rolls of thermal printer paper for fuel management system and Tank Sentinel® consoles |
Legacy ATG Paper Supplies
| Model Number | Description |
|---|---|
| TS-INKRB | TS-550 and TS-5000 ink ribbon |
| TS-TP5000 | TS-550 and TS-5000 impact printer paper |
| TS-TP5000C | 12 rolls of impact printer paper |
- T5 Series consoles shipped after 8/2010 have thermal printers.
Network Expansion Box
| Model | Description |
| FMP-NEB | Network Expansion Box with 8 Ethernet inputs (EVO™ 600/6000 only) |
Featured
Brochures
| Title | Type | Size | |
|---|---|---|---|
| FFS-0918 EVO Module Selection Guide.pdf | 0.97 MB | ||
| FFS-1063 Network Expansion Box Datasheet.pdf | 0.25 MB | ||
| FFS-1040 EVO Series Complete Guide.pdf | 45.8 MB |
Catalogs
| Title | Type | Size | |
|---|---|---|---|
| FFS-0807 (EN) Product Catalogue.pdf | 153.77 MB | ||
| FFS-0367 (UL) Site Starters Ordering Guide.pdf | 64.42 MB | ||
| FFS-1028 2025 UL Ordering Catalog.pdf | 95.28 MB |
Manuals
| Title | Type | Size | |
|---|---|---|---|
| 10000014113 EVO Series Console Install Checklist | 0.09 MB | ||
| TB0124-01 EVO 2_4_6 Autocalibration.pdf | 0.65 MB |